Accredited calibrations

Calibration laboratory accredited by NAH under NAH-2-0133/2015.

(NAH - National Accreditation Authority)

Calibration: procedure that, under specified conditions, determinates a relation between the quantity values with measurement uncertainties provided by measurement standards and corresponding indications with associated measurement uncertainties and uses this to establish a relation for obtaining a measurement result from an indication. Based on calibration results qualification can be performed to determine acceptance of measuring instrument to application requirement.

During accreditation an independent certification body (National Accreditation Authority) tested and confirmed that operation of our calibration laboratory meets MSZ EN ISO/IEC 17025:2005 standard. The certification body performs systematic review in the laboratory between two reaccreditation to provide continuous establishment of accreditation requirements.

Issued calibration certificates fulfil requirements of standard ISO 9000, HACCP, ISO/TS 16949, GMP, GLP, ISO 14001, ISO 17025!

Thermometer calibration (-90...+1200) °C

  • Glass thermometers and other expansion thermometers
  • Electronic thermometers
  • Thermocouples
  • Resistance thermometers
  • Air thermometers (in the range -40...+180 °C, on the spot -10...+100 °C)
  • Transmitters
  • Full measuring loops with resistance thermometers or thermocouples

Calibration of instruments can be performed on the spot or in our laboratory.

 

Term of calibration: 5 workdays! Express calibration: 1 workday.

 

Temperature display calibration (-90...+1200) °C

  • Temperature display calibration of furnaces,
  • dry-heat chambers, thermostats,
  • drying chambers,
  • incubators,
  • refrigerators and freezers, etc.

Calibration of instruments can be performed on the spot or in our laboratory.

 

Term of calibration: 5 workdays! Express calibration: 1 workday.

 

Infrared thermometer calibration (-30...+1200) °C

  • Calibration of infrared thermometers in wide range in our laboratory or on the spot.

 

Term of calibration: 5 workdays! Express calibration: 1 workday.

 

Pressure gauge calibration (abs. 3 µbar...1000 bar overpressure, -1...0 bar vacuum)

  • Absolute and overpressure gauges
  • Vacuum meters
  • Barometers
  • Low vacuum meters
  • Pressure transmitters
  • Pressure calibrators

Calibration of the instruments can be performed on the spot or in our laboratory.

 

Term of calibration: 5 workdays! Express calibration: 1 workday.

 

Relative humidity meter (2...99 rH%) and dewpoint meter (-40...+25 °C) calibration

  • Electronic relative humidity and dew point meters
  • Mechanic relative humidity meters
  • Transmitters

Calibration of the instruments can be performed on the spot or in our laboratory.

 

Term of calibration: 5 workdays! Express calibration: 1 workday.

 

Length meter calibration

  • Calipers (0...1000) mm
  • Depth and height meters (0...600) mm
  • Micrometers (0...600) mm
  • Measuring tapes (0...50) m
  • Rulers (mm resolution)
  • Indicators, inner size meters, built-in micrometers (0...50) mm
  • Thickness meters (0...100) mm
  • Coating thickness meters (0...3) mm
  • Feeler gauges, thickness standards (0.005...25) mm
  • High precision thickness standards (0.005...5) mm

Calibration of the instruments can be performed in our laboratory or on the spot (except measuring tapes and high precision thickness standards).

 

Term of calibration: 5 workdays! Express calibration: 1 workday.

 

Sieve calibration (20 µm...200 mm)

  • Calibration of sieves can be performed in our laboratory or on the spot too.

 

Term of calibration: 5 workdays! Express calibration: 1 workday.

 

 

Watch and stopwatch calibration

  • Watches
  • Stopwatches

Calibration of the instruments can be performed on the spot or in our laboratory.

 

Term of calibration: 5 workdays! Express calibration: 1 workday.

 

Electric instrument calibration

  • DC and AC current meters
  • DC and AC voltage meters
  • DC resistance meters
  • Frequency meters
  • Digital oscilloscopes
  • Insulation meters
  • Flashback testers
  • DC and AC current clamps
  • Resistor decades, resistor gauges
  • Conductivity meters
  • DC and AC voltage sources
  • DC and AC current sources

Calibration of the instruments can be performed on the spot or in our laboratory.

 

Term of calibration: 5 workdays! Express calibration: 1 workday.

 

Tachometer calibration (1...1 000 000) min-1

  • Optical tachometers

Calibration of the instruments can be performed on the spot or in our laboratory.

 

Term of calibration: 5 workdays! Express calibration: 1 workday.

 

Air velocity meter calibration (0.15...40) m/s

  • Thermoanemometers
  • Rotating vanes
  • Anemometer tubes
  • Anemometer transmitters

Calibration of the instruments can be performed on the spot or in our laboratory.

 

Term of calibration: 5 workdays! Express calibration: 1 workday.

 

Torque wrench calibration (0.1...1100) Nm

  • Torque wrenches
  • Torque screwdrivers
  • Torque limiters

Calibration of the instruments can be performed on the spot or in our laboratory.

 

Term of calibration: 5 workdays! Express calibration: 1 workday.

 

Torque meter calibration (0...100) Nm

  • Torque meters
  • Torque wrench and torque screwdriver calibrators
  • Torque transmitters

Calibration of the instruments can be performed on the spot or in our laboratory.

 

Term of calibration: 5 workdays! Express calibration: 1 workday.

 

Non-automatic balance calibration (1 mg...710 kg)

  • Calibration of the instruments can be performed on the spot or in our laboratory.

 

 

Term of calibration: 5 workdays! Express calibration: 1 workday.

 

Force meter calibration (2 N...60 kN)

  • Calibration of the instruments can be performed on the spot or in our laboratory.

 

Term of calibration: 5 workdays! Express calibration: 1 workday.

 

Piston-operated pipette, burette and dispenser calibration (10 µL...160 mL)

  • Calibration of the instruments can be performed in our laboratory.

 

Term of calibration: 5 workdays! Express calibration: 1 workday.

 

Rotameters, nozzles, flowmeters calibration with air by our laboratory (Technicoop Ltd.) which is specialized for this. (0...15000 L/h)

  • Calibration of the instruments can be performed in our laboratory.

 

 

Term of calibration: 5 workdays! Express calibration: 1 workday.